using System;
namespace S7.Net.Protocol
{
/// <summary>
/// Implements a pair of TSAP addresses used to connect to a PLC.
/// </summary>
public class TsapPair
{
/// <summary>
/// The local <see cref="Tsap" />.
/// </summary>
public Tsap Local { get; set; }
/// <summary>
/// The remote <see cref="Tsap" />
/// </summary>
public Tsap Remote { get; set; }
/// <summary>
/// Initializes a new instance of the <see cref="TsapPair" /> class using the specified local and
/// remote TSAP.
/// </summary>
/// <param name="local">The local TSAP.</param>
/// <param name="remote">The remote TSAP.</param>
public TsapPair(Tsap local, Tsap remote)
{
Local = local;
Remote = remote;
}
/// <summary>
/// Builds a <see cref="TsapPair" /> that can be used to connect to a PLC using the default connection
/// addresses.
/// </summary>
/// <remarks>
/// The remote TSAP is constructed using <code>new Tsap(0x03, (byte) ((rack &lt;&lt; 5) | slot))</code>.
/// </remarks>
/// <param name="cpuType">The CPU type of the PLC.</param>
/// <param name="rack">The rack of the PLC's network card.</param>
/// <param name="slot">The slot of the PLC's network card.</param>
/// <returns>A TSAP pair that matches the given parameters.</returns>
/// <exception cref="ArgumentOutOfRangeException">The <paramref name="cpuType"/> is invalid.
///
/// -or-
///
/// The <paramref name="rack"/> parameter is less than 0.
///
/// -or-
///
/// The <paramref name="rack"/> parameter is greater than 15.
///
/// -or-
///
/// The <paramref name="slot"/> parameter is less than 0.
///
/// -or-
///
/// The <paramref name="slot"/> parameter is greater than 15.</exception>
public static TsapPair GetDefaultTsapPair(CpuType cpuType, int rack, int slot)
{
if (rack < 0) throw InvalidRackOrSlot(rack, nameof(rack), "minimum", 0);
if (rack > 0x0F) throw InvalidRackOrSlot(rack, nameof(rack), "maximum", 0x0F);
if (slot < 0) throw InvalidRackOrSlot(slot, nameof(slot), "minimum", 0);
if (slot > 0x0F) throw InvalidRackOrSlot(slot, nameof(slot), "maximum", 0x0F);
switch (cpuType)
{
case CpuType.S7200:
return new TsapPair(new Tsap(0x10, 0x00), new Tsap(0x10, 0x01));
case CpuType.Logo0BA8:
// The actual values are probably on a per-project basis
return new TsapPair(new Tsap(0x01, 0x00), new Tsap(0x01, 0x02));
case CpuType.S7200Smart:
case CpuType.S71200:
case CpuType.S71500:
case CpuType.S7300:
case CpuType.S7400:
// Testing with S7 1500 shows only the remote TSAP needs to match. This might differ for other
// PLC types.
return new TsapPair(new Tsap(0x01, 0x00), new Tsap(0x03, (byte) ((rack << 5) | slot)));
default:
throw new ArgumentOutOfRangeException(nameof(cpuType), "Invalid CPU Type specified");
}
}
private static ArgumentOutOfRangeException InvalidRackOrSlot(int value, string name, string extrema,
int extremaValue)
{
return new ArgumentOutOfRangeException(name,
$"Invalid {name} value specified (decimal: {value}, hexadecimal: {value:X}), {extrema} value " +
$"is {extremaValue} (decimal) or {extremaValue:X} (hexadecimal).");
}
}
}